Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Coronaviruses ; 2(12) (no pagination), 2021.
Article in English | EMBASE | ID: covidwho-2266234

ABSTRACT

The present paper elucidates the conceivable application of two key molecules in SARS-CoV-2 detection of suspected infected persons. These molecules were selected on the basis of the strong interaction between ACE-2 and S protein that allows virus attachment to its host cells;on the other hand, specific immunocompetant effectors are generated by the human immune system during the infection. Several testing procedures are already being used to diagnose SARS-CoV-2 infection, particularly the RT-PCR technique. ELISA and LFIA are possible assays for the employment of shACE-2/ hAc-anti-S (the molecules of interest) as the main agents of the test that confer dual principal functions (capture and detection). The future diagnostic kits involving shACE-2 and hAc-anti-S will possibly be highly sensitive with rapid detection in addition to their advantage of relatively easy conception. They could be largely considered as technically advanced kits in regards to the current SARS-CoV-2 diagnostic immunoassays.Copyright © 2021 Bentham Science Publishers.

2.
Anal Bioanal Chem ; 2022 Nov 22.
Article in English | MEDLINE | ID: covidwho-2242651

ABSTRACT

Serological antibody tests are useful complements of nuclei acid detection for SARS-CoV-2 diagnosis, which can significantly improve diagnostic accuracy. However, antibody detection in serum or plasma remains challenging to do with high sensitivity. In this study, Ag nanoparticles with ultra-thin Au shells embedded with 4-mercaptobenzoic acid (MBA) (AgMBA@Au) were manufactured and then assembled onto Fe3O4 surface by electrostatic interaction to construct the Fe3O4-AgMBA@Au nanoparticles (NPs) with magnetic-Raman-colorimetric properties. Based on the composite nanoparticles, a colorimetric and Raman dual-mode lateral flow immunoassay (LFIA) for ultrasensitive identification of SARS-CoV-2 nucleocapsid (N) protein antibody was constructed. The magnetic nanoparticles (Fe3O4 NPs) were acted as the core and coated a layer of AgMBA@Au particles on the surface by electrostatic interaction to prepare Fe3O4-AgMBA@Au NPs, which can amplify the SERS signal due to multiple AgMBA@Au particles concentrated on a single magnetic nanoparticle. Moreover, the Fe3O4-AgMBA@Au NPs facilitated pre-purifying sample using magnetic separation, and complex matrix interference would be greatly decreased in the detection. The Fe3O4-AgMBA@Au NPs modified with N protein recognized and bound with N protein antibodies, which were trapped on the T-line, forming color band for observing detection. Under optimal conditions, the N protein antibodies could be qualitatively detected in colorimetric mode with the visual limit of 10-8 mg/mL and quantitatively detected by SERS signals between 10-6 and 10-10 mg /mL with 0.08 pg/mL detection limit. The coefficients variations (CV) of intra-assay was 8.0%, whereas of inter-assay was 11.7%, confirming of good reproducibility. Finally, this approach was able to discriminate between positive, negative, and weakly positive samples when detecting 107 clinical serum samples. The process enables highly sensitive quantitative assays that are valuable for evaluating disease processes and guiding treatment. Colorimetric and Raman dual-mode LFIA detection of SARS-CoV-2 N protein antibody based on Fe3O4-AgMBA@Au nanoparticles.

3.
Wellcome Open Res ; 6: 358, 2021.
Article in English | MEDLINE | ID: covidwho-2228543

ABSTRACT

Background: Lateral flow immunoassays (LFIAs) are able to achieve affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine. Methods: This was a prospective diagnostic accuracy study. Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following two doses of SARS-CoV-2 vaccine, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination and subsequent follow up. During the participants visit, finger-prick blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG was detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. A total of 186 paired samples were collected. The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay Results: The LFIA had an estimated sensitivity of 92.0% (114/124; 95% confidence interval [CI] 85.7% to 96.1%) and specificity of 93.6% (58/62; 95% CI 84.3% to 98.2%) using the Abbott assay as reference standard (using the threshold for positivity of 7.10 BAU/ml) Conclusions: Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveillance but does not meet criteria for individual testing.

4.
Beni Suef Univ J Basic Appl Sci ; 12(1): 6, 2023.
Article in English | MEDLINE | ID: covidwho-2235443

ABSTRACT

Background: Coronavirus disease 2019 is a pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection that emerged in late 2019 and has activated an ongoing international public health emergency. SARS-CoV-2 was discovered in Wuhan, China, in December 2019 and rapidly spread to other cities and countries. Currently, SARS-CoV-2 diagnostic tests have relied heavily on detecting viral genes, antigens, and human antibodies. Hence, this review discusses and analyses the existing screening and confirmation tests for SARS-CoV-2, including the real-time reverse transcriptase polymerase chain reaction (RT-PCR), lateral flow immunoassay (LFIA), and enzyme-linked immunosorbent assay (ELISA). Main body: The illustrations of each testing were presented to provide the readers with an understanding of the scientific principles behind the testing methods. The comparison was made by highlighting the advantages and disadvantages of each testing. ELISA is ideal for performing the maximum population screening to determine immunological capacity, although its inability to provide reliable results on the status of the infection. Recently, LFIA has been approved as a quicker way of determining whether a patient is infected at the analysis time without using particular instruments and non-laboratory settings. RT-PCR is the gold-standard approach in terms of sensitivity and specificity. Conclusion: However, the combination of LFIA or ELISA with RT-PCR is also proposed in this review to obtain an adequate level of sensitivity and specificity.

5.
Diagn Microbiol Infect Dis ; 105(4): 115900, 2023 Apr.
Article in English | MEDLINE | ID: covidwho-2178019

ABSTRACT

Lateral flow immunoassays (LFIA) for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies are used for population surveillance and potentially individual risk assessment. The performance of the SureScreen Diagnostics LFIA targeting the spike protein was evaluated in comparison with 3 automated assays (Abbott Alinity-i SARS-CoV-2 IgG, DiaSorin Liaison® SARS-CoV-2 S1/S2 IgG, Wantai SARS-CoV-2 Ab ELISA). We assessed sensitivity using 110 serum samples from PCR confirmed COVID-19 infected patients. Specificity was evaluated using 120 prepandemic samples, including potential cross-reactive antibodies samples. Sensitivity ranged between 93.3% and 98.7% on samples collected >14 days postsymptom onset. All assays achieved a specificity >98%. Moreover, its performance seems not to be affected by Alpha, Beta or Delta variants over a wide range of antibody titers. The latter showed a very good agreement with the Wantai and the Abbott assays and a substantial agreement with the DiaSorin assay. Our data demonstrate the good clinical performance of the SureScreen Diagnostics LFIA for SARS-CoV-2 seroprevalence screening.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19 Testing , Seroepidemiologic Studies , Clinical Laboratory Techniques , Sensitivity and Specificity , Immunoassay , Antibodies, Viral , Immunoglobulin G
6.
2022 IEEE Sensors Conference, SENSORS 2022 ; 2022-October, 2022.
Article in English | Scopus | ID: covidwho-2192058

ABSTRACT

Since the coronavirus disease 2019 occurred, the lateral flow immunoassay (LFIA) test strip has become a global testing tool for convenience and low cost. However, some studies have shown that LFIA strips perform poorly compared to other professional testing methods. This paper proposes a new method to improve the accuracy of LFIA strips using spectral signals. A spectrochip module is applied to disperse the reflected light from the LFIA strips. The obtained spectral signals will be used for supervised machine learning. After training, the trained model has 93.8% accuracy compared to the standard test. This result indicated that the evaluation method based on the spectrum of LFIA strips could enhance the detection performance. © 2022 IEEE.

7.
Talanta ; 255: 124200, 2023 Apr 01.
Article in English | MEDLINE | ID: covidwho-2165885

ABSTRACT

Vaccination is an effective strategy to fight COVID-19. However, the effectiveness of the vaccine varies among different populations in varying immune effects. Neutralizing antibody (NAb) level is an important indicator to evaluate the protective effect of immune response after vaccination. Lateral flow immunoassay (LFIA) is a rapid, safe and sensitivity detection method, which has great potential in the detection of SARS-CoV-2 NAb. In this study, a fluorescent beads-based lateral flow immunoassay (FBs-LFIA) and a latex beads-based LFIA (LBs-LFIA) using double antigen sandwich (DAS) strategy were established to detect NAbs in the serum of vaccinated people. The limit of detection (LoD) of the FBs-LFIA was 1.13 ng mL- 1 and the LBs-LFIA was 7.11 ng mL- 1. The two LFIAs were no cross-reactive with sera infected by other pathogenic bacteria. Furthermore, the two LFIAs showed a good performance in testing clinical samples. The sensitivity of FBs-LFIA and LBs-LFIA were 97.44% (95%CI: 93.15%-99.18%) and 98.29% (95%CI: 95.84%-99.37%), and the specificity were 98.28% (95%CI: 95.37%-99.45%) and 97.70% (95%CI: 94.82%-99.06%) compared with the conventional virus neutralization test (cVNT), respectively. Notably, the LBs-LFIA was also suitable for whole blood sample, requiring only 3 µL of whole blood, which provided the possibility to detect NAbs at home. To sum up, the two LFIAs based on double antigen sandwich established by us can rapidly, safely, sensitively and accurately detect SARS-CoV-2 NAb in human serum.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Neutralization Tests , Immunoassay/methods , Antibodies, Viral , Antigens , Antibodies, Neutralizing
8.
Int J Infect Dis ; 122: 576-584, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2015433

ABSTRACT

OBJECTIVES: Observing the serological cross-reactivity between SARS-CoV-2 and dengue virus (DV), we aimed to elucidate its effect on dengue serodiagnosis and infectivity in a highly dengue-endemic city in India. METHODS: A total of 52 COVID-19 (reverse transcription-polymerase chain reaction [RT-PCR] positive) serum samples were tested in rapid lateral flow immunoassays and DV immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) to detect DV or SARS-CoV-2 IgG/immunoglobulin M. The COVID-19 antibody (Ab) positive samples were subjected to a virus neutralization test (Huh7 cells) using DV type 1 (DV1) clinical isolate. RESULTS: Most (93%) of the SARS-CoV-2 Ab-positive serum samples cross-reacted with DV in rapid or ELISA tests. All were DV RNA and nonstructural protein 1 (NS1) antigen-negative. COVID-19 serum samples that were DV cross-reactive neutralized DV1. Of these, 57% had no evidence of DV pre-exposure (DV NS1 Ab-negative). The computational study also supported potential interactions between SARS-CoV-2 Ab and DV1. CONCLUSION: DV serodiagnosis will be inconclusive in areas co-endemic for both viruses. The COVID-19 pandemic appears to impart a protective response against DV in DV-endemic populations.


Subject(s)
COVID-19 , Dengue Virus , Dengue , Antibodies, Viral , COVID-19/diagnosis , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G , Immunoglobulin M , Neutralization Tests , Pandemics , SARS-CoV-2 , Sensitivity and Specificity , Serologic Tests
9.
Smart Biomedical and Physiological Sensor Technology Xix ; 12123, 2022.
Article in English | Web of Science | ID: covidwho-2005293

ABSTRACT

Accumulating evidence suggests that cytokine storm syndrome (CSS) induced by the SARS-CoV-2 may be the ultimate cause of acute respiratory distress syndrome (ARDS), resulting in severe outcomes of COVID- 19 infection and potentially death. Elevated levels of serum interleukin 6 (IL-6) correlate with the occurrence of respiratory failure, ARDS, and adverse clinical outcomes in many COVID-19 patients. The currently available clinical cytokine tests are costly, time-consuming, and require skilled technicians to execute. There is an unmet need for rapid, affordable, robust, and sensitive tests for cytokine levels. Therefore, this study aimed to develop a cost-effective system for quantitative detection of cytokines that can be used in the point-of-care (POC) format within a few minutes of blood collection. Our approach combines detection based on laser-induced breakdown spectroscopy with a lateral flow immunoassay (LIBS- LFIA) to deliver a quantitative clinical analysis platform with multiplexing capability. Lanthanide-complexed polymers (LCPs) were selected as the labels to provide optimal quantitative performance when sensing signals from the test lines of LFIAs. For a prototype implementation and a proof-of-concept, we targeted IL-6 as it is one of the most critical pro-inflammatory cytokines. Our initial LIBS-LFIA biosensor achieved a limit of detection ( LOD) of 0.2298 mu g/mL of IL-6 within 15 minutes and further sensitivity increase is possible with optimization. Regardless, since high levels of IL-6 are reported for patients in crisis, this is more than adequate to identify patients with highly elevated cytokine levels. Our research provides evidence that rapid and accurate detection of cytokines for clinical diagnosis and prognosis of COVID-19 and other pathogenic infections using LIBS is highly feasible and compatible with the POC format.

10.
4th IEEE International Conference on Design and Test of Integrated Micro and Nano-Systems, DTS 2022 ; 2022.
Article in English | Scopus | ID: covidwho-1973451

ABSTRACT

Lateral Flow Immunoassay (LFIA) has been employed for the development of rapid, low-cost, and relatively simple devices for Covid-19 diagnosis. The proposed approach reports the use of the antibody labeled by Gold nanoparticles for the simultaneous detection of Nucleocapsid protein and Spike protein. A comparison with the results obtained by conventional analytical methods (PCR) has been considered in a significant number of nasopharyngeal swabs;48 and 26 samples from positive and negative individuals respectively. This research provides the basis for the development of a more efficient antigenic test for SARS-Co V-2 detection as a low-cost and quick pre-screening tool. © 2022 IEEE.

11.
Front Bioeng Biotechnol ; 10: 922772, 2022.
Article in English | MEDLINE | ID: covidwho-1924069

ABSTRACT

LFIA is one of the most successful analytical methods for various target molecules detection. As a recent example, LFIA tests have played an important role in mitigating the effects of the global pandemic with SARS-COV-2, due to their ability to rapidly detect infected individuals and stop further spreading of the virus. For this reason, researchers around the world have done tremendous efforts to improve their sensibility and specificity. The development of LFIA has many sensitive steps, but some of the most important ones are choosing the proper labeling probes, the functionalization method and the conjugation process. There are a series of labeling probes described in the specialized literature, such as gold nanoparticles (GNP), latex particles (LP), magnetic nanoparticles (MNP), quantum dots (QDs) and more recently carbon, silica and europium nanoparticles. The current review aims to present some of the most recent and promising methods for the functionalization of the labeling probes and the conjugation with biomolecules, such as antibodies and antigens. The last chapter is dedicated to a selection of conjugation protocols, applicable to various types of nanoparticles (GNPs, QDs, magnetic nanoparticles, carbon nanoparticles, silica and europium nanoparticles).

13.
Klin Lab Diagn ; 65(11): 688-692, 2020 Dec 04.
Article in English | MEDLINE | ID: covidwho-1780383

ABSTRACT

The study presents the results of the creation and evaluation of the diagnostic characteristics of the rapid immunochromatographic test for the qualitative detection and differentiation of IgM/IgG antibodies to SARS-CoV-2 in human serum, plasma, and whole blood "ИХА-COVID-19-IgM / IgG". Have been tested some samples without antibodies to SARS-CoV-2 and a samples with two and one type of specific antibodies. The coincidence of the results of immunochromatographic analysis with the results of the immunochemiluminescent method was 87.2%. Test kit can be use as the rapid diagnostic test in the context of the COVID-19 pandemic and to assess the immune status of convalescents.


Subject(s)
Antibodies, Viral/analysis , COVID-19 Serological Testing , COVID-19/diagnosis , Immunoassay , Immunoglobulin G/analysis , Immunoglobulin M/analysis , Humans
14.
Antib Ther ; 5(1): 55-62, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1684498

ABSTRACT

Although mRNA vaccines against SARS-CoV-2 were highly efficacious against severe illness and hospitalization, they seem to be less effective in preventing infection months after vaccination, especially with the Delta variant. Breakthrough infections might be due to higher infectivity of the variants, relaxed protective measures by the general public in "COVID-19 fatigue", and/or waning immunity post-vaccination. Determining the neutralizing antibody levels in a longitudinal manner may address this issue, but technical complexity of classic assays precludes easy detection and quick answers. We developed a lateral flow immunoassay NeutraXpress™ (commercial name of the test kit by Antagen Diagnostics, Inc.) and tested fingertip blood samples of subjects receiving either Moderna or Pfizer vaccines at various time points. With this device, we confirmed the reported clinical findings that mRNA vaccine-induced neutralizing antibodies quickly wane after 3-6 months. Thus, using rapid tests to monitor neutralizing antibody status could help identify individuals at risk, prevent breakthrough infections, and guide social behavior to curtail the spread of COVID-19.

15.
Int J Mol Sci ; 22(22)2021 Nov 17.
Article in English | MEDLINE | ID: covidwho-1524025

ABSTRACT

Mitigation strategies of the coronavirus disease 2019 (COVID-19) pandemic have been greatly hindered by the continuous emergence of SARS-CoV-2 variants. New sensitive, rapid diagnostic tests for the wide-spectrum detection of viral variants are needed. We generated a panel of 41 monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (NP) by using mice hybridoma techniques. Of these mAbs, nine exhibited high binding activities and were applied in latex-based lateral flow immunoassays (LFIAs). The LFIAs utilizing NP-mAb-7 and -40 had the best sensitivity and lowest limit of detection: 8 pg for purified NP and 625 TCID50/mL for the authentic virus (hCoV-19/Taiwan/4/2020). The specificity tests showed that the NP-mAb-40/7 LFIA strips did not cross-react with five human coronavirus strains or 20 other common respiratory pathogens. Importantly, we found that 10 NP mutants, including alpha (B.1.1.7), beta (B.1.351), gamma (P.1), and delta (B.1.617.2) variants, could be detected by NP-mAb-40/7 LFIA strips. A clinical study (n = 60) of the NP-mAb-40/7 LFIA strips demonstrated a specificity of 100% and sensitivity of 90% in infected individuals with cycle threshold (Ct) values < 29.5. These anti-NP mAbs have strong potential for use in the clinical detection of SARS-CoV-2 infection, whether the virus is wild-type or a variant of concern.


Subject(s)
Antibodies, Monoclonal/immunology , COVID-19/diagnosis , Immunoassay/methods , Nucleocapsid Proteins/immunology , SARS-CoV-2/metabolism , Adolescent , Adult , Aged , Aged, 80 and over , Antigen-Antibody Reactions , COVID-19/virology , Coronavirus/metabolism , Cross Reactions , Female , Humans , Male , Middle Aged , Point-of-Care Systems , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Young Adult
16.
Sens Actuators B Chem ; 351: 130975, 2022 Jan 15.
Article in English | MEDLINE | ID: covidwho-1475063

ABSTRACT

As the world has been facing several deadly virus crises, including Zika virus disease, Ebola virus disease, severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and Coronavirus disease 2019 (COVID-19), lateral flow assays (LFAs), which require minimal equipment for point-of-care of viral infectious diseases, are garnering much attention. Accordingly, there is an increasing demand to reduce the time and cost required for manufacturing LFAs. The current study introduces an equipment-free method of salt-mediated immobilization of nucleic acids (SAIoNs) for LFAs. Compared to general DNA immobilization methods such as streptavidin-biotin, UV-irradiation, and heat treatment, our method does not require special equipment (e.g., centrifuge, UV-crosslinker, heating device); therefore, it can be applied in a resource-limited environment with reduced production costs. The immobilization process was streamlined and completed within 30 min. Our method improved the color intensity signal approximately 14 times compared to the method without using SAIoNs and exhibited reproducibility with the long-term storage stability. The proposed method can be used to detect practical targets (e.g., SARS-CoV-2) and facilitates highly sensitive and selective detection of target nucleic acids with multiplexing capability and without any cross-reactivity. This novel immobilization strategy provides a basis for easily and inexpensively developing nucleic acid LFAs combined with various types of nucleic acid amplification.

17.
Heliyon ; 7(10): e08192, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1471985

ABSTRACT

The dramatic impact of SARS-CoV-2 infection on the worldwide public health has elicited the rapid assessment of molecular and serological diagnostic methods. Notwithstanding the diagnosis of SARS-CoV-2 infection is based on molecular biology approaches including multiplex or singleplex real time RT-PCR, there is a real need for affordable and rapid serological methods to support diagnostics, and surveillance of infection spreading. In this study, we performed a diagnostic accuracy analysis of COVID-19 IgG/IgM rapid test cassette lateral flow immunoassay test (LFIA) assay. To do so, we analyzed different cohorts of blood samples obtained from 151 SARS-CoV-2 RT-PCR assay positive patients (group 1) and 51 SARS-CoV-2 RT-PCR assay negative patients (group 2) in terms of sensitivity, specificity, PPV, NPV and likelihood ratios. In addition, we challenged LFIA with plasma from 99 patients stored during 2015-2017 period. Our results showed that this LFIA detected SARS-CoV-2 IgM and/or IgG in 103 out of 151 (68.21%) samples of group 1, whereas no IgM and/or IgG detection was displayed both in the group 2 and in pre-pandemic samples. Interestingly, IgM and/or IgG positivity was detected in 86 out of 94 (91.49%) group 1 samples collected after 10 days from symptoms onset whereas only 17 out of 57 of group 1 samples obtained before day 10 were positive to SARS-CoV-2 specific antibodies. We also compared the performance of this LFIA test with respect to other four different LFIA assays in 40 serum samples from multiplex RT-PCR positive individuals. Within the limits of the study size, the results demonstrated that COVID-19 IgG/IgM rapid test cassette LFIA assay displayed valid performance in IgM and IgG detection when compared with the other four LFIA assays. Hence, this approach might be considered as an alternative point-of-care procedure for SARS-CoV-2 serological investigation.

18.
Sens Actuators B Chem ; 351: 130897, 2022 Jan 15.
Article in English | MEDLINE | ID: covidwho-1458630

ABSTRACT

The rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at the early stage of virus infection can effectively prevent the spread of the virus and control the epidemic. Here, a colorimetric and fluorescent dual-functional lateral flow immunoassay (LFIA) biosensor was developed for the rapid and sensitive detection of spike 1 (S1) protein of SARS-CoV-2. A novel dual-functional immune label was fabricated by coating a single-layer shell formed by mixing 20 nm Au nanoparticles (Au NPs) and quantum dots (QDs) on SiO2 core to produce strong colorimetric and fluorescence signals and ensure good monodispersity and high stability. The colorimetric signal was used for visual detection and rapid screening of suspected SARS-CoV-2 infection on sites. The fluorescence signal was utilized for sensitive and quantitative detection of virus infection at the early stage. The detection limits of detecting S1 protein via colorimetric and fluorescence functions of the biosensor were 1 and 0.033 ng/mL, respectively. Furthermore, we evaluated the performance of the biosensor for analyzing real samples. The novel biosensor developed herein had good repeatability, specificity and accuracy, which showed great potential as a tool for rapidly detecting SARS-CoV-2.

19.
Front Mol Biosci ; 8: 682405, 2021.
Article in English | MEDLINE | ID: covidwho-1348519

ABSTRACT

The worldwide pandemic of COVID-19 has become a global public health crisis. Various clinical diagnosis methods have been developed to distinguish COVID-19-infected patients from healthy people. The nucleic acid test is the golden standard for virus detection as it is suitable for early diagnosis. However, due to the low amount of viral nucleic acid in the respiratory tract, the sensitivity of nucleic acid detection is unsatisfactory. As a result, serological screening began to be widely used with the merits of simple procedures, lower cost, and shorter detection time. Serological tests currently include the enzyme-linked immunosorbent assay (ELISA), lateral flow immunoassay (LFIA), and chemiluminescence immunoassay (CLIA). This review describes various serological methods, discusses the performance and diagnostic effects of different methods, and points out the problems and the direction of optimization, to improve the efficiency of clinical diagnosis. These increasingly sophisticated and diverse serological diagnostic technologies will help human beings to control the spread of COVID-19.

20.
Am J Epidemiol ; 190(8): 1689-1695, 2021 08 01.
Article in English | MEDLINE | ID: covidwho-1337252

ABSTRACT

Our objective was to estimate the diagnostic accuracy of real-time polymerase chain reaction (RT-PCR) and lateral flow immunoassay (LFIA) tests for coronavirus disease 2019 (COVID-19), depending on the time after symptom onset. Based on the cross-classified results of RT-PCR and LFIA, we used Bayesian latent-class models, which do not require a gold standard for the evaluation of diagnostics. Data were extracted from studies that evaluated LFIA (immunoglobulin G (IgG) and/or immunoglobulin M (IgM)) assays using RT-PCR as the reference method. The sensitivity of RT-PCR was 0.68 (95% probability interval (PrI): 0.63, 0.73). IgG/M sensitivity was 0.32 (95% PrI :0.23; 0.41) for the first week and increased steadily. It was 0.75 (95% PrI: 0.67; 0.83) and 0.93 (95% PrI: 0.88; 0.97) for the second and third weeks after symptom onset, respectively. Both tests had a high to absolute specificity, with higher point median estimates for RT-PCR specificity and narrower probability intervals. The specificity of RT-PCR was 0.99 (95% PrI: 0.98; 1.00). and the specificity of IgG/IgM was 0.97 (95% PrI: 0.92, 1.00), 0.98 (95% PrI: 0.95, 1.00) and 0.98 (95% PrI: 0.94, 1.00) for the first, second, and third weeks after symptom onset. The diagnostic accuracy of LFIA varies with time after symptom onset. Bayesian latent-class models provide a valid and efficient alternative for evaluating the rapidly evolving diagnostics for COVID-19, under various clinical settings and different risk profiles.


Subject(s)
COVID-19 Nucleic Acid Testing/statistics & numerical data , COVID-19 Serological Testing/statistics & numerical data , COVID-19/diagnosis , Immunoassay/statistics & numerical data , Real-Time Polymerase Chain Reaction/statistics & numerical data , Antibodies, Viral/blood , Bayes Theorem , COVID-19/immunology , Humans , Latent Class Analysis , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL